Reagent Filling Machine - Meiji Sensing
01 Test tube gripper loading
Optical fiber sensor PG1+PD-E32
When loading transparent test tubes, it is necessary to detect the presence of material in the loading area so that the gripper can be activated to pick up the material.
Since the installation space is limited, the sensor does not need an excessively long detection range. Considering the variety of tube materials and the desire for post‑pandemic versatility, a fiber‑optic sensor with comprehensive functionality is recommended. With mechanical adjustments, this solution not only eliminates the previous manual feeding workload but also significantly increases throughput: manual feeding manages 60 tubes per minute, whereas the optimized system both replaces manual labor and boosts speed to at least 160 tubes per minute.
① Fiber optic amplifiers can adjust the sensor brightness threshold according to the varying reflectivity of different tube materials.
② It employs a through-beam operating principle, ensuring more stable detection performance.
③ This equipment has numerous moving components (servo motors and variable-frequency drives can interfere with sensors). Fiber-optic sensors use optical transmission; the amplifier and fiber-optic head are mounted in separate locations, so adequate shielding of the amplifier is sufficient to prevent unnecessary electromagnetic interference.
02 Status monitoring of gripper cylinders, material-pushing cylinders, etc.
cylinder sensor MR-C8-C-S
Cylinder material handling, cap gripping, and the clamping of the cylinder used to select caps all require pneumatic cylinder sensors to provide feedback on the cylinder’s switching status to the PLC control center. The MR-C8-C-S cylinder sensor not only supplies real-time position data for the cylinder but also continuously monitors its own operating condition as well as that of the pneumatic actuator, with a fast response time of up to 5 microseconds.
03 Bottle Cap Feeding
One-to-four optical fiber sensor PC1+PD-S4Q3-30
To improve efficiency, it is necessary to simultaneously perform feeding and inspection at four positions of the caps coming from the vibratory bowl feeder and to pick up four caps at once. However, costs must not increase significantly; therefore, this four-head fiber-optic sensor and a higher-performance fiber-optic amplifier were selected. The principle is the same as that used for tube feeding, but this solution eliminates the cost of three sets of fiber-optic sensors and the labor costs previously associated with this station, while greatly enhancing operational efficiency and stability.
04 Information Storage and Traceability
Smart Code Reader RCD-AI100-S
After labeling, the QR codes must be read and stored. Simply install the RCD-AI100-S smart barcode reader above the conveyor belt to automatically save the information to the system in real time, enabling testing or medical institutions to retrieve data for the relevant batch of test tubes without having to search manually—making the process convenient and efficient. This feature also significantly enhances competitiveness among similar devices.